BKBTM - G-335C INDUSTRIAL X-RAY FIXER WRKG STRENGTH
- MSDS: BKBTM
- Manufacturer: AGFA CORP
- Product Name: G-335C INDUSTRIAL X-RAY FIXER WRKG STRENGTH
- National Stock Number: 6750-00N014043
Product Identification
Product ID:G-335C INDUSTRIAL X-RAY FIXER WRKG STRENGTH
MSDS Date:06/01/1988
FSC:6750
NIIN:00N014043
MSDS Number: BKBTM
Responsible Party
RIDGEFIELD PARK, NJ 07660
US
Emergency Phone: 303-623-5716,800-424-9300(CHEMTREC)
Info Phone: 201-440-2500, 212-971-0260
Cage: HO790
Contractor
Telephone: 210-440-2500
Cage: 59710
Ingredients
THIOSULFURIC ACID, DIAMMONIUM SALT (AMMONIUM THIOSULFATE)
CAS: 7783-18-8
RTECS: XN6465000
Fraction By Weight: 15-20%
1)
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 1-5%
ACETIC ACID (SARA III)
CAS: 64-19-7
RTECS: AF1225000
Fraction By Weight: 1-5%
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM/15 STEL; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ALUMINUM SULFATE (SARA III)
CAS: 10043-01-3
RTECS: BD1700000
Fraction By Weight: 0-1%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
SULFURIC ACID (SARA III)
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 0-1%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:MAY CAUSE IRRITATION.
SKIN:NO DERMAL IRRITATION AS PER TESTS PERFORMED. INHAL:NORMALLY NO
PROBLEM, BUT INHALATION OF MIST COULD CAUSE RESPIRATORY IRRITATION.
INGEST:MAY CAUSE IRRITATION OF M UCOUS MEMBRANES OR DIGESTIVE
TRACT. CHRONIC:NO CHRONIC EFFECTS ASSOCIATED WITH MATERIALS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:IMMEDIATELY FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST
15 MINUTES. GET MD. SKIN:FLUSH AFFECTED AREAS PROMPTLY W/WATER FOR
15 MINUTES. REMOVE CONTAMINATED CLOTHING. IN CASE OF CONTINUED
IRRITATI ON CALL MD. INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING
(GIVE O*2/ARTF RESP) . INGEST:GET MD IMMEDIATELY.
Fire Fighting
Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:EVACUATE PERSONNEL TO SAFE AREA. KEEP
PERSONNEL REMOVED AND UPWIND OF FIRE. WEAR NIOSH/MSHA APPROVED SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMISSION OF
TOXIC FUMES OF SO*2 IS POSSIBLE.
Accidental Release
Spill Release Procedures:USE APPROP PERSONAL PROTECTIVE EQUIPMENT
DURING CLEAN UP. DIKE SPILL. PREVENT LIQUID FROM ENTERING SEWERS,
WATERWAYS OR LOW AREAS. SOAK UP WITH SAWDUST, SAND, OIL DRY OR
OTHER ABOSRBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN WELL VENTILATED AREA. KEEP
CONTAINER TIGHTLY CLOSED. DO NOT STORE W/INCOMPATIBLE MATERIALS.
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
AREA WHERE THEY MAY BECOME CONTAMINATED WITH MATERIAL.
Exposure Controls
Respiratory Protection:NONE NEEDED WITH WORKING MIXTURES AND NORMAL
ROOM VENTILATION. IF TLV EXCEEDED, USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PRODUCT IN
UNVENTILATED AREAS.
Protective Gloves:CHEMICAL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CHEMICAL APRONS RECOMMENDED.
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE AND BEFORE
EATING, SMOKING OR USING SANITARY FACILITIES .
Supplemental Safety and Health
WASTE DISP METH:AUTHORITY AND MAY REQUIRE PRETREATMENT. DISPOSE OF
I/A/W FEDERAL, STATE AND LOCAL REGULATIONS .
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:21.07
Vapor Density:=WATER
Spec Gravity:1.110
pH:4.20
Evaporation Rate & Reference:0.3
Solubility in Water:100%
Appearance and Odor:CLEAR AND COLORLESS, SLIGHT SULFUR DIOXIDE ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG ACIDS, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SO*X, CO*2, CARBON MONOXIDE, AMMONIA.
Disposal
Waste Disposal Methods:RECOVER NONUSABLE FREE LIQ &/OR CONTAM WATER &
DISPOSE OF IN APPRVD/PERMITTED TREATMENT SYS. REMOVE NONUSABLE
SOLID MATL &/OR CONTAM SOIL FOR DISPOSAL IN APPRVD/PERMITTED
LANDFILL. DISCHARGE TO SEWER REQUIRES APPROVAL OF PERMITTING (SEE
SUPP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.